 OM1805NKM OM1815NKM OM1812NKM
HERMETIC TO-3 FIXED VOLTAGE REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp Precision Positive Regulators In Hermetic JEDEC TO-3 Package FEATURES
* * * * * * Output Voltages: 5V, 12V, 15V Output Voltages Set Internally to 1% Built-In Thermal Overload Protection Short Circuit Current Limiting Similar To Industry Standards 7805, 7812, 7815 Hi-Rel Screening Available
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed metal TO-3 package. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages 1% of nominal voltage. These units are ideally suited for Military applications where a hermetically sealed package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number 5962-8778201 YX 5962-8777601 YX 5962-8855301 YX Omnirel Part Number OM1805NKM OM1812NKM OM1815NKM
3.3
4 11 R0
3.3 - 51
OM1805NKM - OM1815NKM
ABSOLUTE MAXIMUM RATINGS @ 25C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55C to + 150C Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to + 150C Typical Power/Thermal Charateristics: Rated Power @ 25 C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3W Thermal Resistance qJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3C/W qJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29C/W a ELECTRICAL CHARACTERISTICS 5 Volt
Parameter Output Voltage Symbol VOUT VIN = 10V, Io = 500mA, -55C TA 125C (unless otherwise specified) Min. 4.92 Max. 5.08 5.15 Unit V V
Test Conditions TA = 25C VIN = 7.5V to 20V IO = 5mA to 1.0A, P < 20 W
*
4.85
Line Regulation (Note 1) (Note 4)
VRLINE
VIN = 7.5V to 20V
5
mV mV mV mV mV mV mV mV mA mA mA
*
VIN = 8.0V to 12V
12 4
*
Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp IO = 5mA to 1.0Amp IO = 250mA to 750 mA
10 12
* *
25 6 15 6
Standby Current Drain
ISCD DISCD (Line) DISCD (Load) VDO IO (pk) IDS DVIN DVOUT NO DVOUT Dt TA = 25C, DVOUT = 100mV, IO = 1.0A TA = 25C VIN = 35V 1.5 IO = 5mA to 1000mA VIN = 7.5V to 20V
Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2)
* * *
6.5 0.8
0.5
mA
2.5 3.3 1.2
V A A A dB dB
*
f =120 Hz, DVIN = 10V (Note 3) TA = 25C, f =10 Hz to 100KHz TA = 25C, t = 1000 hrs. 66
2.8
3.3
Ripple Rejection
*
60 40
Output Noise Voltage (Note 3) Long Term Stability (Note 3)
V/V RMS
75
mV
Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = 35V. 3. If not tested, shall be guaranteed to the specified limits. The * denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA.
3.3 - 52
OM1805NKM - OM1815NKM ELECTRICAL CHARACTERISTICS 12 Volt
Parameter Output Voltage Symbol VOUT VIN = 19V, Io = 500mA, -55C TA 125C (unless otherwise specified) Min. 11.88 Max. 12.12 12.36 Unit V V
Test Conditions TA = 25C VIN = 14.5V to 27V IO = 5mA to 1.0 A, P < 20W
*
11.64
Line Regulation (Note 1) (Note 4)
VRLINE
VIN = 14.5V to 27V
18
mV mV mV mV mV mV mV mV mA mA mA
*
VIN = 16V to 22V
50 9
*
Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp IO = 5mA to 1.0 Amp IO = 250mA to 750 mA
30 32
* *
60 20 40 6.0
Standby Current Drain
ISCD DISCD (Line) DISCD (Load) VDO IO (pk) IDS DVIN DVOUT NO DVOUT Dt DVOUT = 100mV, IO = 1.0A TA = 25C VIN = 35V IO = 5mA to 1000mA VIN = 15V to 30V
Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection
* * * *
1.5
6.5 0.8
0.5
mA
2.5 3.3 1.2
V A A A dB dB
*
f =120 Hz, DVIN = 10V (Note 3) TA = 25C, f =10 Hz to 100KHz TA = 25C, t = 1000 hrs. 61
2.8
*
54 40
Output Noise Voltage (Note 3) Long Term Stability (Note 3)
V/V RMS
120
mV
Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = 35V. 3. If not tested, shall be guaranteed to the specified limits. The * denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA.
3.3
MECHANICAL OUTLINE
1.53 REF. 0.875 MAX. 0.135 MAX. 0.450 0.250 0.312 MIN. SEATING PLANE 0.043 0.038 2 PLCS. 0.225 0.205 0.161 0.151 0.525 R. MAX. 1.197 1.177 0.675 0.655
2 1
0.188 R. MAX.
0.440 0.420
Pin Connection Pin 1: Input Pin 2: Output Case: Ground
3.3 - 53
OM1805NKM - OM1815NKM
ELECTRICAL CHARACTERISTICS 15 Volt
Parameter Output Voltage Symbol VOUT VIN = 23V, Io = 500mA, -55C TA 125C (unless otherwise specified) Min. 14.8 Max. 15.2 15.4 Unit V V
Test Conditions TA = 25C VIN = 18.5V to 30V IO = 5mA to 1.0 A, P < 20W
*
14.6
Line Regulation (Note 1) (Note 4)
VRLINE
VIN = 17.5V to 30V
20
mV mV mV mV mV mV mV mV mA mA mA
*
VIN = 20V to 26V
50 15
*
Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp IO = 5mA to 1.0 Amp IO = 250mA to 750 mA
25 35
* *
75 21 45 6.0
Standby Current Drain
ISCD DISCD (Line) DISCD (Load) VDO IO (pk) IDS DVIN DVOUT NO DVOUT Dt TA = 25C, DVOUT = 100mV, IO = 1.0A TA = 25C VIN = 35V 1.5 IO = 5mA to 1000mA VIN = 18.5V to 30V
Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection
* * *
6.5 0.8
0.5
mA
2.5 3.3 1.2
V A A A dB dB
*
f =120 Hz, DVIN = 10V (Note 3) TA = 25C, f =10 Hz to 100KHz TA = 25C, t = 1000 hrs. 54
2.8
*
52 40
Output Noise Voltage (Note 3) Long Term Stability (Note 3)
V/V RMS
150
mV
Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = 35V. 3. If not tested, shall be guaranteed to the specified limits. The * denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
3.3
3.5 3
PEAK OUTPUT
2.5
DROPOUT VOLTAGE
100
RIPPLE REJECTION
Tj = -55C
2
Output Current (A)
2.5 1.5 2
Tj = 25C IOUT = 500mA
Ripple Rejection (dB)
IOUT = 1A
80
VOUT = 5V
60
1.5 1
Tj = 150C
1
IOUT = 0A
40
VIN - V = 8VDC +3.5Vrms IOUT = 1A Tj = 25C
0.5
DVOUT = 100MV
0.5 0 0
20
DVOUT = 100mV
5
10
15
20
25
30
35
0 -75 -50 -25
0
25 50 75 100 125 150
0 10 100 1k 10k 100k
Input To Output Differential (V)
Junction Temperature (C)
Frequency (Hz)
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246


▲Up To Search▲   

 
Price & Availability of OM1815NKM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X